Technical data

Standard drive mechanism group: 2m

Design
Cable-
speed
Motor power
at 40% ED
120 switching cycles/h
Motor-
speed
Load capacity¹
new
old
m/min
kW
rpm.
kg
10/2
III
36
0,75
2800
100
10/4
I
18
0,55
1400
160
10/6
II
12
0,37
900
160
10/8
-
9
0,27
700
160
20/2
VI
20
0,75
2800
180
20/4
IV
10
0,55
1400
250
20/6
-
6
0,37
900
250
20/8
V
5
0,27
700
250

Standard design with special cable speeds upon request

Special design drive mechanism group: 1Am

Design
Cable-
speed
Motor power
at 25% ED
80 switching cycles/h
Motor-
speed
Load capacity¹
new
m/min
kW
rpm.
kg
11/2
36
0,90
2800
125
11/4
18
0,66
1400
200
11/6
12
0,45
900
200
11/8
9
0,33
700
200
21/2
20
0,90
2800
225
21/4
10
0,66
1400
320
21/6
6
0,45
900
320
21/8
5
0,33
700
320

1) always relative to the bottom cable length in cases of multi-layers. Don't forget winding factor!

Cable-Ø and maximum useable cable take-up per strand at: single cable grooved drum2

Standard design

Design
for max. 2 cable layers
with flanged pulley ring: A0
or with
flanged pulley enlargement: A1-A3
Cable-Ø
1.Layer
2.Layer
at A0
at A1
at A2
at A3
new
mm
m
m
m
m
m
m
10/2 11/2
5
23,0
48,2
101
182
340
483
10/4 11/4
6
19,4
41,2
64
109
214
335
10/6 11/6
6
10/8 11/8
6
20/2 21/2
6
20/4 21/4
6
20/6 21/6
6
20/8 21/8
6

Cable-Ø and max. useable cable take-up per strand at: single-cable grooved drum 22

Winch with extended drum

Design
-440 long-
Additional letter:L
-up to 3000 long-
Addtitional letter:Lx
Cable-Ø
1.Layer
2.Layer
1.Layer
2.Layer
neu
mm
m
m
m
m
10/2 11/2
5
46,0
95,1
bis 343
bis 700
10/4 11/4
6
39,2
81,7
bis 294
-
10/6 11/6
6
10/8 11/8
6
20/2 21/2
6
20/4 21/4
6
20/6 21/6
6
20/8 21/8
6

2) Two reserve windings have already been deducted on the cable take-up.
The maximum cable take-up is calculated taking 1.5 x cable diameter as being the amount of flanged pulley protrusion.